Skip to content

Flow Restrictors

AMI Flow Restrictors for Home RO Systems
Designed for use in residential reverse osmosis systems to restrict the flow on the drain (reject) line, keeping the membrane pressurized and controlling the recovery ratio of the system. The flow restrictor must be properly sized according to the flow of the RO membrane system. The recommended sizes per flow rate are listed in the below tables.

It is recommended that the flow restrictor is replaced each time an RO membrane is replaced in order to keep your system working at optimum performance, as scale build up can occur and clog the capillaries. Additionally, if changing to a different flow-rate membrane element, the flow restrictor must be changed to the appropriate size as well.

Available in several styles including encapsulated capillaries (in both quick connect and male threaded end connections) and inserts for use in fittings. Encapsulated capillary style flow restrictors should be installed in the membrane reject line between the housing outlet and the drain. Insert style flow restrictors should be inserted in the fitting between the membrane housing reject outlet and the tubing that leads to the drain.

Benefits of Flow Restrictors for Home RO Systems

  • Calibrated to the appropriate flow for use with common home RO membrane system flow rates
  • Maintains pressure across the membrane element which is an integral part of the reverse osmosis process
  • Easily installed
  • Available in several styles to suit your system’s configuration

Encapsulated Capillary Flows Restrictors with Quick Connect End Connections

¼” QC Tube Fittings

Quick Connect Flow Restrictors for Home RO

Model No.

Restrictor Flow
(mL per Minute)

Recommended For Membrane (GPD)

H-R2051QC

150

10

H-R2052QC

200

16

H-R2061QC

250

18

H-R2062QC

300

24

H-R2063QC

350

30

H-R2064QC

420

36

H-R2068QC

600

50/55

H-R2074QC

650

55

H-R2071QC

750

65

H-R2069QC

850

75

H-R1000QC

1000

100

Encapsulated Capillary Flows Restrictors with Male Threaded End Connections

¼” Male NPT Threads.
Requires ¼” FNPT compression nut (sold separately)

Male Threaded Flow Restrictors for Home RO Systems

Model No.

Restrictor Flow
(mL per Minute)

Calibrated For Membrane (GPD)

H-R2051M

150

10

H-R2061M

250

18

H-R2064M

420

36

H-R2065M

550

50

H-R2069M

850

75

F-1050-004

Nut for M Flow Restrictor ¼” FNPT

 

Insert-Style Flows Restrictors

For use with a ⅛” Male Fitting (sold separately)

Flow Restrictor Inserts for Home RO Systems

Model No.

Restrictor Flow
(mL per Minute)

Calibrate For Membrane (GPD)

H-R2066

300

24

H-R2087

350

30

H-R2067

400

35

 

Flows Restrictor Insert in Fitting

AMI flow restrictor insert pre-installed into a ¼”T x ¼”M NPT AMI Quick Connect Elbow Fitting

Flow Restrictor Elbows for Home RO Systems

Model No.

Restrictor Flow
(mL per Minute)

Calibrate For Membrane (GPD)

H-R2057QC

250

18

H-R2087QC

350

30

 

Features of Flow Restrictors for Home RO Systems

  • Encapsulated Capillary Construction
  • Various Options for Installation
  • Sized to Maintain Appropriate Recovery Ratio for Common RO System Flows

Applications for Flow Restrictors for Home RO Systems

  • Point of Use (POU) Drinking Water Systems
  • Home RO Systems
  • Office
  • Institutions
  • Lab