Skip to content

Myron L Water Quality Monitors and RO System ControllersThe unique circuitry of our 750 Series II Conductivity, TDS and Resistivity Monitor/controllers guarantees accurate and reliable measurements. Drift-free performance is assured by "field proven" electronics, including automatic DC offset compensation and highly accurate drive voltage.

Since Temperature Compensation is at the heart of accurate water measurement, all Myron L Monitor/controllers feature a highly refined and precise TC circuit. This feature perfectly matches the water temperature coefficient as it changes. All models are corrected to 25°C. The TC may be disabled to conform with USP requirements.

Benefits of Myron L Water Quality Monitor System Controllers

  • Ensures Water Quality
  • Built-in electronic calibration allows for fast quality checks.
  • A push-to-test button makes setpoint checks easy, while the internal alarm set discourages unauthorized adjustments.
  • Standard on all controller models is a heavy-duty, 10-amp output relay, operating on either increasing or decreasing readings. Bright green/red LEDs indicate readings above or below setpoint.
  • Digital and Analog 750 Series II models have an IP65/NEMA 4X water-resistant & corrosion-proof rated enclosure. At 152 x 122 mm/6 x 4.8 in., all models are suitable for panel, bench or surface mounting.
  • Affordable
  • Ease of Operation
  • Low Maintenance

Myron L 750 Series Resistivity Monitors/Controllers

Model No.

Monitors

Range

Display

Function

751II-11

Resistivity

0-20 Megohm

Analog Meter

Monitor Only

751II-13

Resistivity

0-5 Megohm

Analog Meter

Monitor Only

752II-11

Resistivity

0-20 Megohm

Analog Meter

Monitor & Controller

752II-13

Resistivity

0-5 Megohm

Analog Meter

Monitor & Controller

753II-11

Resistivity

0-20 Megohm

Digital

Monitor & Controller

753II-13

Resistivity

0-5 Megohm

Digital

Monitor & Controller

754II-11

Resistivity

0-20 Megohm

Digital

Monitor Only

754II-13

Resistivity

0-5 Megohm

Digital

Monitor Only

CS10

Sensor for Resistivity Monitors- Polypropylene – 0.05 cell const.

 

Myron L 750 Series Condutivity/TDS Monitors/Controllers

Model No.

Monitors

Range

Display

Function

756II-111

EC (Electrical Conductivity)

0-50 µS

Analog Meter

Monitor Only

756II-113

EC (Electrical Conductivity)

0-100 µS

Analog Meter

Monitor Only

757II-111

EC (Electrical Conductivity)

0-50 µS

Analog Meter

Monitor & Controller

757II-113

EC (Electrical Conductivity)

0-100 µS

Analog Meter

Monitor & Controller

758II-111

EC (Electrical Conductivity)

0-50 µS

Digital

Monitor & Controller

758II-113

EC (Electrical Conductivity)

0-100 µS

Digital

Monitor & Controller

758II-119

EC (Electrical Conductivity)

0-1000 µS

Digital

Monitor & Controller

759II-111

EC (Electrical Conductivity)

0-50 µS

Digital

Monitor Only

759II-113

EC (Electrical Conductivity)

0-100 µS

Digital

Monitor Only

756II-110

TDS (Total Dissolved Solids)

0-20 ppm

Analog Meter

Monitor Only

756II-112

TDS (Total Dissolved Solids)

0-50 ppm

Analog Meter

Monitor Only

765II-114

TDS (Total Dissolved Solids)

0-100 ppm

Analog Meter

Monitor Only

765II-116

TDS (Total Dissolved Solids)

0-200 ppm

Analog Meter

Monitor Only

756II-120

TDS (Total Dissolved Solids)

0-1000 ppm

Analog Meter

Monitor Only

757II-110

TDS (Total Dissolved Solids)

0-20 ppm

Analog Meter

Monitor & Controller

757II-112

TDS (Total Dissolved Solids)

0-50 ppm

Analog Meter

Monitor & Controller

757II-116

TDS (Total Dissolved Solids)

0-200 ppm

Analog Meter

Monitor & Controller

757II-118

TDS (Total Dissolved Solids)

0-500 ppm

Analog Meter

Monitor & Controller

757II-120

TDS (Total Dissolved Solids)

0-1000 ppm

Analog Meter

Monitor & Controller

758II-110

TDS (Total Dissolved Solids)

0-20 ppm

Digital

Monitor & Controller

758II-112

TDS (Total Dissolved Solids)

0-50 ppm

Digital

Monitor & Controller

758II-114

TDS (Total Dissolved Solids)

0-100 ppm

Digital

Monitor & Controller

758II-114-4A
(4-20mA Output)

TDS (Total Dissolved Solids)

0-100 ppm

Digital

Monitor & Controller

758II-116

TDS (Total Dissolved Solids)

0-200 ppm

Digital

Monitor & Controller

758II-120

TDS (Total Dissolved Solids)

0-1000 ppm

Digital

Monitor & Controller

758II-120-4A
(4-20mA Output)

TDS (Total Dissolved Solids)

0-1000 ppm

Digital

Monitor & Controller

758II-122

TDS (Total Dissolved Solids)

0-2000 ppm

Digital

Monitor & Controller

759II-110

TDS (Total Dissolved Solids)

0-20 ppm

Digital

Monitor Only

759II-112

TDS (Total Dissolved Solids)

0-50 ppm

Digital

Monitor Only

759II-120

TDS (Total Dissolved Solids)

0-1000 ppm

Digital

Monitor Only

 

Sensors for Myron L 750 Series Monitors/Controllers

All Myron-L monitors and controllers require a sensor (sold separately). Recommended sensors for most applications are listed in the table below. View the “Sensor Selection Guide” in the Literature tab for additional sensor options.

Sensor Model No.

For Monitor/ Controller Type

Description

CS10

Resistivity

Polypropylene – 0.05 Cell Constant

CS51

Conductivity & TDS

Polypropylene – 1.0 Constant for use between 0-10 and 0-20,000. Includes temperature sensor for ATC. Modular polypropylene bushing.

 

Myron L Analog Resistivity Monitor and System Controller

Myron L Digital Resistivity Monitor and System Controller

Myron L Resistivity Sensor CS10

Myron L Analog Monitor System Controller

Myron L Digital Monitor System Controller

Myron LCS10 Resistivity Sensor
CS51 Conductivity Sensor

Myron L 750 Series Water Quality Monitor Features

  • 34 Conductivity/TDS ranges:  0- 1 microsiemens/ppm to 0-200 millisiemens/ppt
    7 Resistivity ranges from 0-200 Kilohms to 0-20 Megohms-cm
  • Choice of 3½ digit display or analog meter
  • Automatic temperature compensation to 77°F (25°C )
  • Isolated 0-10 VDC Recorder Output standard
  • IP65/NEMA 4X water resistant and corrosion proof enclosure
  • Built-in electronic calibration
  • Single set point/alarm standard
  • Adjustable setpoint hysteresis
  • Solid State 24 VDC  Output
  • 10 amp relay operates on choice of increasing or decreasing reading
  • LEDs show "above/below" Alarm/control status
  • Push-to-test set point check
  • Internal set point discourages unauthorized adjustment
  • Selectable 115/230 VAC
  • Reliable, easily installed sensors
  • CE Certified
  • Made in USA

Myron L 750 Series Monitors are CE CertifiedMyron L Instruments Made in USA

Applications for TDS/Conductivity Monitor System Controllers:

  • Reverse Osmosis Systems
  • Process Control
  • Seawater Desalination Systems
  • Waste Treatment Systems
  • Food Processing
  • Plating
  • Power Plants
  • Laboratories
  • Printing
  • Aquaculture
  • Agriculture
  • Environmental Studies
  • Medical
  • Boilers (250 psi @ 205°C)
  • Cooling Towers

Applications for Resistivity Monitor System Controllers:

  • Ultrapure Water Treatment Systems
  • Deionization (DI) Water Treatment Systems
  • Distillation Water Treatment Systems
  • Electronics
  • Pharmaceuticals
  • Laboratories
  • Food Processing
  • Plating
  • Power Plants
  • Boiler Condensate
  • Process Control

Myron L 750 Series Options

  • Second Alarm/control Module
  • 4-20 mA Isolated Output
  • Piezo Electric Alarm
  • 3½ or 4½ Digit Backlit Display
  • Temperature Module
  • 24 VAC Isolated Power Supply
  • 24 VDC Isolated Power Supply

Related Water Quality Monitoring Products