Platinum Series UV Systems – NSF Certified – 316 SS

Retired Model   Suggested Replacement  Comparison of Retired part and Suggested Replacement   
 Flow Rate, GPM 
(Retired/
Replacement) 
Inlet/Outlet
(Retired/
Replacement)
Chamber Dimensions
(Retired/
Replacement)  
Monitored
(Retired/
Replacement) 
NSF Certified
(Retired/
Replacement)  
 SPV-200  n/a 2.6/(n/a)   ½”  MNPT/(n/a) 17.8" × 3.5" /(n/a)    YES/YES YES/n/a
SPV-410  n/a  6/(n/a)  ¾”F-1”M/(n/a) 26.0" × 3.5" /(n/a)   YES/YES  YES/n/a
SPV-600  PRO10 8/10   ¾”F-1”M/ 1"F-1¼"M  30.7 × 3.5/ 22"x4"  YES/YES  YES/YES
SPV-740  PRO10 12/10  ¾”F-1”M/ 1"F-1¼"M   39.4 × 3.5/ 22"x4"  YES/YES  YES/YES
SPV-950  PRO20  15/20 ¾”F-1”M/ 1"F-1¼"M   44.5 × 3.5/ 31"x4"  YES/YES  YES/YES

Platinum Series UV Systems – 304SS (Non-Listed)

Retired Model   Suggested Replacement  Comparison of Retired part and Suggested Replacement   
 Flow Rate, 16 mJ/cm2 GPM 
(Retired/
Replacement) 
 Flow Rate, 40 mJ/cm2 GPM 
(Retired/
Replacement) 
Inlet/Outlet
(Retired/
Replacement)
Chamber Dimensions
(Retired/
Replacement)  
Monitored
(Retired/
Replacement)  
NSF Certified
(Retired/
Replacement)  
SP320-HO VH410M 34/34 13/14  ¾”F-1”M/  ¾”F-1”M  22.8"×3.5"/  YES/YES  NO/NO
SP410-HO VH410M  45/34 18/14  1"MNPT/  ¾”F-1”M 26.0"×3.5"/    YES/YES  NO/NO 
SP-600HO VP600M 60/40 26/22  1"MNPT/ 1" MNPT 30.7"×3.5"/   YES/YES   NO/NO 
SP-740HO VP950M  60/60 31/35 1½"MNPT/ 1½"MNPT 39.4"×3.5"/   YES/YES   NO/NO 
SP-950HO VP950M   60/60 39/35 1½"MNPT/ 1½"MNPT 44.5"×3.5"/   YES/YES   NO/NO 

Replacement Parts for Sterilight Platinum Series UV Ultraviolet Systems Purchase Replacement UV Lamps and Components from our Online Distributor

For Sterilight System

UV Lamp, Sterilume™

Quartz Sleeve

 

SP320-HO

S320RL-HO

QS-320

Spare Parts for Sterilight Ultraviolet UV Disinfection Systems

SP410-HO & SPV-410

S410RL-HO

QS-410

SP600-HO & SPV-600

S600RL-HO

QS-600

SP740-HO & SPV-740

S740RL-HO

QS-740

SP950-HO & SPV-950

S950RL-HO

QS-950

Note:  Replacement lamps and sleeves come with 2 O-Rings

 

Part Number

For Sterilight System

Description

SPC-ICE-HO

ALL

Controller, Platinum Ice

254NM-FP2

ALL “SPV”

UV Sensor Assembly, Flow-Pace™ 254nm for NSF Certified Systems, w/3’ Sensor Cable

254NM-FP1

ALL “HO”

UV Sensor Assembly, Flow-Pace™ 254nm for Non-Validated Systems, w/3’ Sensor Cable

OR-12N

ALL

O-Ring for Sensor Assembly

RN-001

ALL

Aluminum Retaining Nut

OR-212

ALL

O-Ring for Quartz Sleeve/Aluminum Nuts

SP008

ALL

Quartz Sleeve Spring

410076

ALL

3 ½” Clamp

Downloadable Literature for Sterilight Platinum Series UV Ultraviolet Systems

Ultraviolet Disinfection Technical Information

Note:  Microorganisms require varying UV dose levels for destruction. Some of the common organisms and their corresponding dosage level are shown below.
1.  2-log reduction,  2.  4-log reduction 

Microorganism

Dose (mJ/cm²)

E. Coli²

6.6

Cryptosporidium parvum¹

<10

Giardia lamblia¹

<10

Hepatitus Virus¹

8

Microorganism

Dose (mJ/cm²)

Influenza Virus¹

6.6

Shigella dysenteriae²

4.2

Legionella pnuemophila²

3.8

Salmonella paratyphi²

6.1

Typical Point of Entry Installation for Viqua Sterilight UV System